The upgrade itself went smoothly, but half the switches disappeared from CloudVision afterwards. Here's what broke and the pre-check I now never skip.
Switch upgrades are routine until they aren't. This was a planned EOS upgrade on a pair of data center leaf switches. The new image booted, MLAG came back, BGP re-converged… and the switches showed as offline in CloudVision.

Quick background
TerminAttr is the agent on each Arista switch that streams state to CloudVision (CVP/CVaaS). If it isn't running or can't authenticate, CloudVision loses visibility, and with it config push, compliance and change control.
What we saw

Two problems stacked up:
- The TerminAttr version bundled with the old image was older than CloudVision expected after the upgrade.
- The onboarding token referenced in the daemon config had expired, so the agent couldn't re-register after the reload.
The fix during the window
- Installed the supported TerminAttr extension version and made it boot-persistent.
- Generated a fresh onboarding token in CloudVision and updated the token file on the switch.
- Restarted the daemon (
shutdown/no shutdownunderdaemon TerminAttr). - Confirmed streaming status and that the devices showed as Active in the inventory.
My upgrade pre-check list now
- ✅ Image MD5/SHA verified on flash
- ✅ Boot variable set and
show boot-configchecked - ✅ MLAG config-sanity clean, no inconsistencies
- ✅ BGP neighbor and prefix counts saved before the change
- ✅ TerminAttr version compatibility checked against the CloudVision release
- ✅ Onboarding token validity checked
- ✅ Rollback image kept on flash
Takeaway
An upgrade isn't done when the switch forwards packets. It's done when monitoring and management can see it again.